Circulating current suppression can effectively improve the reliability and redundancy of parallel inverter systems. The mechanism and influencing factors of the low- and high-frequency zero-sequence circulating current (ZSCC) are analyzed in this study.. In order to solve the circulation problem caused by the parameter difference of parallel high frequency resonant inverters, a current equalization control strategy is proposed. Based on a mechanism analysis and the built. . Parallel-connected modular inverters are widely used in high-power applications to increase the power capacity of the system. These modular inverters ofer convenient maintenance and an adjustable power rating. However, when the inverters share a common DC source and AC bus, a circulating current is. . In order to solve the circulation problem caused by the parameter dif-ferenceofparallelhighfrequencyresonantinverters,acurrentequalizationcontrol strategy is proposed. The mathematical model between the series and parallel res-onant impedance of the parallel inverters and the circulation is. . This paper presents a full digital control strategy for parallel connected modular inverter systems. Each modular inverter is a high frequency (HF) AC link inverter which is composed of a HF inverter and a HF transformer followed by a cycloconverter. To achieve equal sharing of the load current and.